This code is stored when the DME self test fails. Delete any stored codes. Start and run the car for 30 seconds. Turn off the ignition for 30 seconds. Rerun the diagnosis. If the same fault recurs, the DME control unit must be replaced.
This code is stored when the engine temperature is >70C and the Oxygen Sensor value is out of range or not present. Check the Oxygen Sensor wiring and the operation of the sensor. The value should fluctuate between 0.02 and 0.85V. Slow fluctuation indicates a polluted Oxygen sensor and negative values indicate a damaged sensor. Note: Cars without Catalytic Convertors will incorrectly store this code.

Tags : catalytic convertors, bmw repair, oxygen sensor, engine temperature, negative values, self test, fluctuation, rerun, diagnosis, bmw, cars
If you see unrelated pdf files with the description or copyrighted material published, please report to us, we'll correct/delete it it as soon as possible.NONE OF THOSE MATERIALS ARE HOSTED IN THIS SERVER NOR UPLOADED BY ME IN SOMEONE'S SERVERS.  Read our DISCLAIMER for more detail.
We are neither affiliated with authors and brands nor responsible for its content and change of content.
Information contained herein is provided "as is" without warranty of any kind, either expressed or implied, including any warranty of merchantability or fitness for a particular purpose. In no event shall ANYONE be held liable for any loss of profit, special, incidental, consequential, or other similar claims.