Assembly :
1. Install the new oxygen sensor in the exhaust manifold.
2. Cut off one end of the tube that went from the exhaust manifold to the EGR valve and remove the tube nut from it. Install the saucer shaped freeze plug into the hole in the exhaust manifold where you removed the EGR tube. Secure the freeze plug by tightening the now free tube nut down against the freeze plug.
3. Install the new distributor (The distributor is shipped with an indexing lock pin and will not rotate. DO NOT REMOVE THE PIN UNTIL THE DISTRIBUTOR IS INSTALLED). NOTE: If you think the engine may have moved from TDC, make sure the engine is at TDC on the crankshaft balancer (Figure 3). The oil pump should be in the position shown in Figure 4. Install the hold-down clamp and remove the yellow locking pin (Figure 5).

Tags : crankshaft balancer, egr tube, oxygen sensor, freeze plug, kit assembly, locking pin, exhaust manifold, egr valve, free tube, oil pump, crankshaft, fuel injection, hold down, clamp, liter
If you see unrelated pdf files with the description or copyrighted material published, please report to us, we'll correct/delete it it as soon as possible.NONE OF THOSE MATERIALS ARE HOSTED IN THIS SERVER NOR UPLOADED BY ME IN SOMEONE'S SERVERS.  Read our DISCLAIMER for more detail.
We are neither affiliated with authors and brands nor responsible for its content and change of content.
Information contained herein is provided "as is" without warranty of any kind, either expressed or implied, including any warranty of merchantability or fitness for a particular purpose. In no event shall ANYONE be held liable for any loss of profit, special, incidental, consequential, or other similar claims.